intelligence_src_cd638cf167c7c119d6
- Source-provided label
- Publisher RSS metadata
- Evidence class
- mentioned in report
- Confidence
- Not reported
- Observed
- Sep 23, 2026 18:22 UTC
- Retrieved
- Oct 14, 2026 03:25 UTC
Overview Imprivata Enterprise Access Management (EAM), an authentication and single sign-on platform for enterprise and clinical environments, contains a vulnerability in versions 26.2.6 and below. The product provides no supported mechanism to rotate its RSA key pair after deployment, meaning the same key pair is used indefinitely to generate the appliance's X.509 certificate. Description CVE-2026-82356 Imprivata EAM uses an RSA key pair to generate the X.509 certificate that identifies the appliance to the clinical workstations, Electronic Health Record (EHR) platforms, and shared-device workflows that rely on it for authentication. After reviewing the product documentation and engaging Imprivata support, it was confirmed that no supported mechanism exists to rotate this RSA key pair after deployment. Using a single RSA key pair indefinitely for certificate generation violates cryptographic best practices. Because the key cannot be rotated, an attacker who obtains the private key retains a valid, trusted appliance identity for as long as the deployment remains in service, with no supported means to revoke or replace it short of redeploying the product. Impact An attacker who obtains the private key, for example through backup exfiltration, a hypervisor snapshot, or privileged access to the appliance filesystem, can impersonate the appliance to any endpoint that trusts its certificate. Because Imprivata EAM sits directly in the authentication path, this allows persistent, difficult-to-detect interception of authentication traffic across every application the appliance brokers, including SSO tokens, session assertions, and credentials for EHR and clinical systems. If perfect forward secrecy is not enforced, previously captured traffic can also be decrypted retroactively. Because the key pair cannot be rotated, this access persists until the appliance is redeployed. Solution Unfortunately, Imprivata could not be reached to coordinate this case. The vendor is aware of the issue, which they are tracking internally, and is reported to be working toward a resolution. No fix or timeline has been provided at the time of publication. Until a fix is available, affected users should protect the appliance's private key by restricting filesystem and administrative access, securing backups and hypervisor snapshots, and enforcing perfect forward secrecy on upstream connections to limit the impact of any key compromise. Acknowledgements Thank you to Frank "5y5tem5" Mileto for reporting this issue. This document was written by Alexander Curtis.
53d56f046150ea6563a9acbd2af168e8cc15f49109c9dd9c7718d700a961d08eNetwork indicators are visibly defanged. This page does not make them clickable or send them to another service.
No validated file hashes or network indicators are stored for this record.
This record contains metadata and attribution only. It does not host, download, unpack, render, or execute malware samples.
Sources represented on this page. Publication and observation dates describe the content; successful batch dates describe local collection. A recent batch does not certify complete coverage or current provider availability.
1 sources: 0 stale, 0 needing attention, 0 paused, 0 unverified.
Stale means older than twice the recorded collection interval, with a minimum of one hour; without an interval, the threshold is 24 hours. Cached content remains available while a feed is stale, paused, or unverified.