Disclosure summary
Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default.
Source-reported weakness categories
CWE-798, NVD-CWE-noinfo
Source-specific records & product guidance
Sources retain their own attribution and scoring. Follow the original record to confirm affected versions, fixed releases, and configuration conditions.
NIST National Vulnerability Database · NVD-CVE-2025-41109
Open original source · Updated Oct 08, 2026
Only CPE matches marked vulnerable=true are indexed. AND/OR platform conditions must be checked in the original NVD record.
| Vendor | Product / association | Version / bounds |
|---|---|---|
| ghostrobotics | vision_60_firmware | 0.27.2 |
Original records & references
- NIST NVD record
- CVE Program record
- www.incibe.es — Third Party Advisory
PUBLISHED 2025-10-22T05:15:36-04:00
MODIFIED 2026-10-08T07:10:00-04:00
INGESTED 2026-10-08T12:35:06-04:00